Skip to Content

Deck and bulkhead glands

Penetrations specifically developed for the British Royal Navy
At sea

Penetrations specifically developed for the British Royal Navy, but are now sold worldwide to various maritime applications, ships, oil platforms, gas carriers, cruise liners and more.

  • Lloyds certified Pressure tested to 5 bar 
  • Certified to DEF STAN 02-510/1
  • NATO stock coded
  • Supplied complete with flexible seal
  • Available with EMC
  • No additional parts or on site machining required
  • Glands supplied in electro plated mild steel with brass nuts
  • Ability to fix to Metric threaded Conduit
  • Lloyds certified to A 60 Approval (metal housing)

A flexible penetration for single cables. No additional parts or on site machining required. Glands supplied in electro plated mild steel with brass nuts. Ability to fix to Metric threaded Conduit. Available with EMC/EMI protection.

DB cable gland

Correct and safe installations

To achieve the highest standard of safety, a cable or pipe transit must be installed correctly. As there are many different types of frame – which may be either welded, bolted or glued into position – and insert block, it is essential that installers known when to use the most appropriate installation method.

For more information, please view following instructions, videos or download manuals as PDFs.

For more information visit Instructions and manuals

150 mm (5.90 “) gland assembly with 30 mm ( 1.18”) long thread

Ref Cable range
min
Cable range
max
Metric
thread
Flange
diameter
Nut A/F Weight
D&B 16-150-30 4 mm 0.16" 16 0.63" M33x2 70 mm 2.76" 46 mm 1.81" 1.45 kg 3.20 lb
D&B 25-150-30 13 mm 0.51" 25 0.98" M50x2 80 mm 3.25" 65 mm 2.56" 2.62 kg 5.77 lb
D&B 35-150-30 23 mm 0.91" 35 1.31" M60x2 100 mm 3.94" 80 mm 3.15" 3.51 kg 7.74 lb
D&B 50-150-30 32 mm 1.26" 50 1.97" M75x2 120 mm 4.72" 100 mm 3.94" 5.05 kg 11.13 lb
D&B 60-150-30 48 mm 1.89" 60 2.36" M90x2 150 mm 5.98" 120 mm 4.72" 7.42 kg 16.36 lb

 

150 mm (5.90 “) gland assembly with 70 mm ( 2.76”) long thread

Ref Cable range
min
Cable range
max
Metric
thread
Flange
diameter
Nut A/F Weight
D&B 16-150-70 4 mm 0.16" 16 0.63" M33x2 70 mm 2.76" 46 mm 1.81" 1.63 kg 3.59 lb
D&B 25-150-70 13 mm 0.51" 25 0.98" M50x2 80 mm 3.25" 65 mm 2.56" 3.03 kg 6.68 lb
D&B 35-150-70 23 mm 0.91" 35 1.31" M60x2 100 mm 3.94" 80 mm 3.15" 4.14 kg 9.13 lb
D&B 50-150-70 32 mm 1.26" 50 1.97" M75x2 120 mm 4.72" 100 mm 3.94" 5.71 kg 12.59 lb
D&B 60-150-70 48 mm 1.89" 60 2.36" M90x2 150 mm 5.98" 120 mm 4.72" 8.08 kg 17.81 lb

 

75 mm (2.95 “) gland assembly with 30 mm ( 1.18”) long thread

Ref Cable range
min
Cable range
max
Metric
thread
Flange
diameter
Nut A/F Weight
D&B 16-75-30 4 mm 0.16" 16 0.63" M33x2 70 mm 2.76" 46 mm 1.81" 1.02 kg 2.25 lb
D&B 25-75-30 13 mm 0.51" 25 0.98" M50x2 80 mm 3.25" 65 mm 2.56" 1.81 kg 3.99 lb
D&B 35-75-30 23 mm 0.91" 35 1.31" M60x2 100 mm 3.94" 80 mm 3.15" 2.48 kg 5.47 lb
D&B 50-75-30 32 mm 1.26" 50 1.97" M75x2 120 mm 4.72" 100 mm 3.94" 3.55 kg 7.83 lb
D&B 60-75-30 48 mm 1.89" 60 2.36" M90x2 150 mm 5.98" 120 mm 4.72" 6.20 kg 13.67 lb

 

75 mm (2.95 “) gland assembly with 70 mm ( 1.18”) long thread

Ref Cable range
min
Cable range
max
Metric
thread
Flange
diameter
Nut A/F Weight
D&B 16-75-70 4 mm 0.16" 16 0.63" M33x2 70 mm 2.76" 46 mm 1.81" 1.19 kg 2.62 lb
D&B 25-75-70 13 mm 0.51" 25 0.98" M50x2 80 mm 3.25" 65 mm 2.56" 2.11 kg 4.65 lb
D&B 35-75-70 23 mm 0.91" 35 1.31" M60x2 100 mm 3.94" 80 mm 3.15" 2.94 kg 6.48 lb
D&B 50-75-70 32 mm 1.26" 50 1.97" M75x2 120 mm 4.72" 100 mm 3.94" 4.20 kg 9.26 lb
D&B 60-75-70 48 mm 1.89" 60 2.36" M90x2 150 mm 5.98" 120 mm 4.72" 6.95 kg 15.32 lb

 

          Standard Gland parts                                  EMC Conversion part

Lloyd´s Register
A class fire, Gas tightness (catastrophic), Water tightness (catastrophic)
MED
A class fire, Gas tightness (catastrophic), Water tightness (catastrophic)

For more information visit Certificates

Similar products

LSJ

LSJ

Longitudinal Sealing Cable Joint

Longitudinal Sealing Cable Joint is used to run an electrical cable through a tank/pipe between two pressure-tight sections.

See specs and variations  for LSJ
PHP

PHP

Longitudinal sealed pressure hull cable penetrator

Longitudinal sealed pressure hull cable penetrator is used to run an electrical cable through a pressure hull.

See specs and variations  for PHP
SR cable gland

SR cable and pipe seals

Sealing cables or pipes between 4 and 100 mm

The seal can be supplied cut to allow pre terminated cable to be installed. It is supplied with a center core providing a seal prior to cable installation.

See specs and variations  for SR cable and pipe seals
MSR cable gland

MSR glands

Sealing up to 8 cables between 4 and 32 mm

The MSR glands are designed to seal up to 8 cables between 4 and 32 mm (0.16” and 1.26”) diameter.

See specs and variations  for MSR glands